The anchorage of Brånemark and ITI implants of different lengths. I. An experimental study in the canine mandible

Authors: Bernard J-P.; Szmukler-Moncler S.; Pessotto S.; Vazquez L.; Belser U.C.

Source: Clinical Oral Implants Research, Volume 14, Number 5, October 2003 , pp. 593-600(8)

Publisher: Blackwell Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

:

The anchorage of machined Brånemark and ITI TPS-coated implants of various lengths was investigated in an animal model. Brånemark fixtures 7 and 10 mm long and ITI implants 6 and 10 mm long were inserted in the mandible of dogs and were reverse-torqued after 3 months of healing. The failing mode was different for the two implant systems. For the ITI implants, loosening coincided with the peak reverse-torque values. For the Brånemark fixtures, two reverse-torque values were identified and recorded, a ‘start to rotate’ and a peak value. The ‘start to rotate’ values for the 7 and 10 mm Brånemark fixtures were 36.67 and 38.57 Ncm, respectively, the peak values were 61.88 and 69.13 Ncm. The increase in implant length from 7 to 10 mm did not significantly improve the anchorage. The mean reverse-torque values for the 6- and 10-mm ITI implants were 104.66 and 192.25 Ncm, respectively; the difference was statistically significant. The mean removal torque of the 6-mm ITI implant was higher than the 7- and 10-mm Brånemark implants. It is suggested that the distinct anchorage magnitude and the distinct loosening patterns registered for both implant systems might be related to the various surface states. The latter might account for the different failure tendencies mentioned in the literature for short Brånemark and ITI implants. To cite this article:

Bernard J-P, Szmukler-Moncler S, Pessotto S, Vazquez L, Belser UC. The anchorage of Brånemark and ITI implants of different lengths. I. An experimental study in the canine mandible.

Clin. Oral Impl. Res.14, 2003; 593–600

Keywords: Brånemark implants; healing period; implant length; ITI implants; machined surface; reverse-torque; TPS

Document Type: Research article

DOI: 10.1034/j.1600-0501.2003.120908.x

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$50.16 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A