Abstract:

.Background:

High reproducibility of test measurements is often considered an indication of high reliability of test results. The aim of the current study was to analyse the role of the traditional perimetric reliability indices, False Negative and False Positive responses, and Fixation Losses, as indicators of test reliability in comparison with threshold reproducibility in patients with suspect or manifest glaucoma.

Methods:

Perimetry was performed in one eye in each of 76 patients. Each eye was tested twice within approximately one week using the Humphrey II 30-2 Sita Standard program. Frequencies of False Positive and False Negative answers, and rates of Fixation Losses were related to threshold reproducibility and to general field status as expressed by Mean Deviation from age-normal threshold values using stepwise multiple linear regression analysis.

Results:

Substantial field loss was associated both with low threshold reproducibility (p<0.0001) and with increased frequency of False Negative answers (p=0.047). The traditional reliability indices contributed marginally compared to amount of field loss when predicting threshold reproducibility; the coefficient of determination decreased non-significantly from 0.37 to 0.33 when excluding the three reliability indices as explanatory variables from the regression model. Frequencies of False Positive answers and Fixation Losses showed no association to field status or to threshold reproducibility.

Conclusion:

Reliability of visual field test results in patients with glaucoma expressed as threshold reproducibility, can be predicted by amount of field loss alone, and traditional patient reliability indices contribute surprisingly little in this regard.

Keywords: perimetry; visual field; glaucoma; false responses; reliability indices

Document Type: Original article

Affiliations: 1: Department of Ophthalmology, Malmö University Hospital, Sweden

The full text article is temporarily unavailable.

We apologise for the inconvenience. Please try again later.

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A