Does a positive end-expiratory pressure-induced reduction in stroke volume indicate preload responsiveness? An experimental study

Authors: Lambert1; Sloth; Smith2; Hansen1; Koefoed-Nielsen; Tønnesen3; Larsson

Source: Acta Anaesthesiologica Scandinavica, Volume 51, Number 4, April 2007 , pp. 415-425(11)

Publisher: Blackwell Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background: 

Increases in positive end-expiratory pressure (PEEP) are often associated with cardiovascular depression, responding to fluid loading. Therefore, we hypothesized that if stroke volume (SV) is reduced by an increase in PEEP this reduction is an indicator of hypovolemia or preload responsiveness, i.e. that SV would increase by fluid administration at zero end-expiratory pressure (ZEEP). The relationship between the cardiovascular response to different PEEP levels and fluid load as well as the relation between change in SV as a result of change in preload (Frank-Starling relationship) were evaluated in a porcine model. In addition, other measures of fluid status were assessed. Methods: 

Eight, 20-22 kg, anesthetized, mechanically ventilated pigs were subjected to 0, 10, and 20 cm H2O PEEP at 10% (of estimated blood volume) hypovolemia, normo- and 10% hypervolemia, and to ZEEP at 20% hypervolemia. SV, cardiac output, intrathoracic blood volume and airway, esophageal, vascular pressures, stroke volume variations, left ventricular end-diastolic and end-systolic areas and respiratory variations in the diameter of the inferior vena cava were obtained. Results: 

At hypovolemia and normovolemia, 10 cm H2O PEEP induced a significant decrease in SV, while no change occurred at 10% hypervolemia. SV measured at ZEEP increased from hypovolemia to normovolemia and 10% hypervolemia, while no change was found between 10% and 20% hypervolemia. The sensitivity and specificity decrease in SV by PEEP indicating an increase in SV by fluids was 60-88% and 67%, respectively, depending on the volemic (preload) levels. Conclusion: 

Although the overall results suggest that a change in SV by PEEP might predict preload responsiveness, the individual response of SV by 10 cm H2O PEEP and of the successive fluid administration seemed to be dependent on where on the Frank-Starling curve the heart function was located.

Keywords: Preload responsiveness; positive end-expiratory pressure; cardiac output

Document Type: Research article

DOI: 10.1111/j.1399-6576.2007.01248.x

Affiliations: 1: Department of Anesthesia and Intensive Care Medicine, Center for Cardiovascular Research, Aalborg Hospital, Århus University Hospitals, Aalborg 2: Center for Medical Model Based Decision Support, Aalborg University, Aalborg, Denmark 3: Clinical Institute, Århus University, Århus

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$50.39 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A