Coiling of lumbar epidural catheters

Authors: Lim, Y. J.1; Bahk, J. H.1; Ahn, W. S.1; Lee, S. C.1

Source: Acta Anaesthesiologica Scandinavica, Volume 46, Number 5, May 2002 , pp. 603-606(4)

Publisher: Blackwell Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background:

The difficulties in threading an epidural catheter to vertebral levels remote to the puncture level have been well documented. This study was undertaken to determine the length that a single orifice epidural catheter can be threaded into the lumbar space without coiling (coiling length), and whether this is affected by the direction of the epidural needle bevel. Methods:

Forty-five young male patients scheduled for surgery under epidural analgesia were enrolled. The epidural space was identified using a midline approach at the L2−3 or L3−4 interspace with the loss of resistance to air technique. A 19-G single-orifice epidural catheter (Flextip PlusTM, Arrow International, Inc, Reading, PA, USA) was inserted through a Tuohy needle oriented either cephalad (n=20) or caudad (n=25). During insertion, the path and the position of the catheter tip was determined by fluoroscopy using iohexol dye. Results:

The median coiling length was 2.8 cm, ranging from 1.0 to 8.0 cm. Only 13% of epidural catheters could be threaded 4 cm beyond the tip of the needle without coiling. No significant difference was found in coiling length between the cephalad group (2.9 cm) and the caudad group (2.5 cm). Conclusion:

This study demonstrates that coiling length is independent of whether the bevel of the Tuohy needle is directed cephalad or caudad. We recommend that an optimal insertion depth of an end-hole single orifice catheter is 3 cm.

Keywords: epidural anesthesia; catheter technique

Document Type: Research article

DOI: 10.1034/j.1399-6576.2002.460520.x

Affiliations: 1: Department of Anesthesiology and Clinical Research Institute, Seoul National University Hospital, Korea

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$50.16 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A