Abstract:

Objective. 

To summarize major complications and outcome for patients receiving percutaneous closure of atrial septal communications. Design. 

The Medline database and the United States Food and Drug Administration manufacturer and user facility device experience databases (MAUDE) were searched for reports related to complications with atrial septal occluding devices. The medical literature documenting complication rates for these devices were reviewed and summarized. The MAUDE database complication reports were compared with those reported in the medical literature using national implant estimates. Outcome. 

The MAUDE database correlated in the type of complications most frequently encountered with each device. However, based on estimated total implant numbers, there is a higher incidence of major complications, including death. AGA devices had a 0.3% erosion/perforation rate with a higher morbidity and mortality (29%) than previously reported. NMT devices had a lower incidence of erosion/perforation rate of 0.05%. Embolization rates for the NMT devices were also lower than published European studies, possibly reflecting the US restriction of the device for closure of patent foramen ovale. Thrombus was more frequently encountered on the NMT device. Both AGA and NMT devices have been shown to be safe and effective alternatives to cardiac surgery. The MAUDE database correlated, with a very low overall complication rate, but showed a higher estimated major complication rate than the medical literature. These data demonstrate the difficulty in quantifying rare complications in the premarketing analysis and the obligation providers have to report and evaluate complications through vigilant postmarketing surveillance.

Keywords: ASD; PFO; Complication; Device; Catheterization; Atrial Septal Defect

Document Type: Research article

DOI: 10.1111/j.1747-0803.2007.00107.x

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$50.16 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A