Characteristics of Mechanical Heart Valve Cavitation in a Pneumatic Ventricular Assist Device

Authors: Lee, Hwansung; Taenaka, Yoshiyuki

Source: Artificial Organs, Volume 32, Number 6, June 2008 , pp. 453-460(8)

Publisher: Blackwell Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

: 

In previous studies, we investigated the mechanism of mechanical heart valve (MHV) cavitation and cavitation intensity with a nonsynchronized experiment system. Our group is currently developing a pneumatic ventricular assist device (PVAD), and in this study we investigated MHV cavitation intensity in the PVAD using a synchronized analysis of the cavitation images and the acoustic signal of cavitation bubbles. A 23-mm Medtronic Hall valve with an opening angle of 70° was mounted in the mitral position of the PVAD after removing the sewing ring. A function generator provided a square signal, which used the trigger signal of the electrocardiogram R wave (ECG-R) mode of the control-drive console for circulatory support. This square signal was delayed by a delay circuit and was then used as the trigger signal for a pressure sensor and a high-speed video camera. The data were stored using a digital oscilloscope at a 1-MHz sampling rate, and then the pressure signal was band-pass filtered between 35 and 200 kHz using a digital filter. The band-pass filtered root mean squared (RMS) pressure and cavitation cycle duration were used as an index of cavitation intensity. The cavitation bubbles were concentrated at the valve stop, and the cavitation cycle duration and RMS pressure increased as the heart rate and driving pressure increased. At the low valve-closing velocity, bubble cavitation was observed near the valve stop. However, at the fast valve-closing velocity, cloud cavitation was observed. A high-frequency signal wave was generated when the bubbles collapsed. The cavitation cycle duration and RMS pressure increased as the valve-closing velocity increased linearly. 

Keywords: Pneumatic ventricular assist device; Mechanical heart valve; Cavitation

Document Type: Research article

DOI: 10.1111/j.1525-1594.2008.00564.x

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$50.16 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A